Fixed Competitive Price Water System Flow Meter - High pressure,High temperature filtration – Taige

TG-170 Series HTHP Filter Presses

TG-170 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long.  The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.

Model and Specifications 

Name 

HTHP Filtration 

Model 

TG-170-00

TG-170-01

TG-170-02

TG-171-01

TG-171-02

Dimensions (cm)

15×20×53cm

20×20×57cm

26×25×56cm

21×31×76cm

35×31×76cm

Weight (kg)

21kg

24kg

26kg

40kg

45kg

Input Voltage 

AC220V±5%            50Hz

Power KW

0.4W

 

 

1KW

1.5KW

Maximum Temperature(℃)

150

232

Maximum Pressure MPa

4.2MPa

7.1MPa

Maximum Returning Pressure MPa

0.7MPa

3.5MPa

Mesh Area cm2

22.6cm2

Cup Capacity (ml

175ml

500ml

 

Name  

HTHP Dynamic Filtration 

Return Pressure Receiver 

Model 

TG-172-50

TG-170-20

TG-171-20

Dimensionss (cm)

46×25×78cm

10×6×13cm

10×6×16cm

Weight (kg)

75kg

1.5kg

1.9kg

Power Supply 

AC220V±5%     50Hz

PowerKW) 

1.2W

Speed Adjustable Range r/min

0800 r/min

Maximum Temperature of  Static Filtration (℃)

232

Maximum Temperature of Dynamic Temperature  Filtration (℃)

150

Maximum Pressure MPa

7.1MPa

0.7MPa

3.5MPa

Maximum Return Pressure MPa

3.5MPa

Mesh Area cm2

22.6cm2

Cup Capacity ml

500ml

 

 

TG-70 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long.  The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.

WhatsApp Online Chat !